DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044A4804 Cty ALA Rte 260 PM R0.8/R2.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
John Ruzic |
Date Reported: |
07/26/2016 |
|
Address: |
TL Number: |
262461 |
||
City: |
||||
Project Name: REPLACE GUARDRAIL, RESTORE PORTAL BUILDING, INSTALL CCTV |
||||
Prime Contractor: GORDON N. BALL, INC.. |
||||
Sample Taken Date: |
06/28/2016 |
Mix Design: |
na |
|
Contractor: Unknown |
Location: ALAMEDA COUNTY IN ALAMEDA AND OAKLAND AT POSEY TUBE AND WEBSTER STREET TUBE |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.27 | 157392 | 5567.5 | 1 |
2 | 6.01 | 28.37 | 154761 | 5455.1 | 2 |
DIME Test ID: 2016-06-28-10-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5510
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing