Print Report | Back to Sample Detail

Sample Record for 2023-12-22-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-12-22-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/22/2023
Date that the sample was received by the laboratory/organization performing the testing: 01/05/2024
The quantity of what the sample constitutes: 45
A brief description of the sample: F1554 gr 55 ATR
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): na
Heat Number(s): 8000022067
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: F1554 Gr 55 (ATR)
Bolt Length(s): 12"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 8000022067
Rocap Test Requirement(s): na
Lubricant Requirements(s): na

Test Results

Test 1 of 8

DIME Test ID: 2023-12-22-3-2
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
180000220670.4980.195736089705723.4aauvinen
UTM 67kip
Temperature 72 f

Test 2 of 8

DIME Test ID: 2023-12-22-3-3
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
280000220670.4980.195734189693223.7aauvinen
UTM 67kip
Temperature 72 f

Test 3 of 8

DIME Test ID: 2023-12-22-3-4
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
380000220670.4980.195733519712624.8aauvinen
UTM 67kip
Temperature 72 f

Test 4 of 8

DIME Test ID: 2023-12-22-3-5
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
480000220670.4980.195731189704524.9aauvinen
UTM 67kip
Temperature 72 f

Test 5 of 8

DIME Test ID: 2023-12-22-3-6
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 8000022067
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 0.75 in
Bolt Length 12 in
Gage Type Pass

Test 6 of 8

DIME Test ID: 2023-12-22-3-7
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 8000022067
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 0.75 in
Bolt Length 12 in
Gage Type Pass

Test 7 of 8

DIME Test ID: 2023-12-22-3-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 8000022067
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 0.75 in
Bolt Length 12 in
Measurement Average 5.05 mils

Test 8 of 8

DIME Test ID: 2023-12-22-3-9
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/12/2024
Date Tested: 01/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 8000022067
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 0.75 in
Bolt Length 12 in
Measurement Average 5.83 mils