Print Report | Back to Sample Detail

Sample Record for 2023-12-08-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214708 DEA: 07323904 EFIS: 0716000072 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-1-21.3/28.4
Work Description: COLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location Description: VENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
Contractor Name: C. A. Rasmussen, Inc.
Contractor Address: 28548 Livingston Avenue, Valencia, CA 91355
Resident Engineer: Alfred Ira Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-12-08-26
TL Number from the TL Form: 120823C
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/11/2023
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2" RHMA-G 326122 SAT VLO
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-625
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Saticoy

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 326122 SAT VLO

Test Results

Test 1 of 2

DIME Test ID: 2023-12-08-26-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/15/2023
Date Tested: 12/14/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7359.3 grams
Mass of oven-dry sample in air for Sample 1 1554.4 grams
Mass of container filled with the sample and water for Sample 1 8268.3 grams
Temperature of Water 7 °F
Specific Gravity for Sample 1 2.408
Theoretical maximum density at 25°C (77°F) 149.9 lb/ft^3

Test 2 of 2

DIME Test ID: 2023-12-08-26-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/15/2023
Date Tested: 12/14/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4023.0 g
Mass of the specimen and specimen basket assembly prior to ignition 5565.3 g
Mass of HMA Sample prior to ignition 1542.3 g
Corrected Asphalt Binder Content 7.58 %
Mass Loss 117.0 g
Mass of aggregate remaining after ignition 1425.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.01 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C