Print Report | Back to Sample Detail

Sample Record for 2023-12-11-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215348 DEA: 060U4204 EFIS: 0616000004 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-12-11-10
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/11/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/11/2023
The quantity of what the sample constitutes: 449 T
A brief description of the sample: 3/4" HMA coldfeed
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Ashlan

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 16
Sublot number: 1
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2023-12-11-10-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/12/2023
Date Tested: 12/12/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 2874.4 g
Mass of the specimen and specimen basket assembly prior to ignition 4935.5 g
Mass of HMA Sample prior to ignition 2061.1 g
Corrected Asphalt Binder Content 4.83 %
Mass Loss 109.8 g
Mass of aggregate remaining after ignition 1951.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.36 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2023-12-11-10-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/18/2023
Date Tested: 12/13/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test: This result is from the D.O. lab
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 1.9 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-12-11-10-1AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)12/12/2023Not scheduledArthur MillsCT D06 - Millbrook Field Laboratory