Print Report | Back to Sample Detail

Sample Record for 2023-12-11-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994245 DEA: 051H4304 EFIS: 0516000073 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-21.4/21.9
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGES.
Location Description: SANTA BARBARA COUNTY IN GOLETA FROM ROUTE 101/217 SEPARATION TO 0.3 MILE NORTH OF SAN JOSE CREEK BRIDGE
Contractor Name: MCM CONSTRUCTION
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Manny Yogarajah Structure Rep.: Fabian Velasco

Sample Information

DIME Sample ID: 2023-12-11-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 12/11/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2023
The quantity of what the sample constitutes: 4 of 117
A brief description of the sample: #6 X 1'-6" Ultimate Welded Hoops Lot 114
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RKR Steel Welding

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 221422
Hoop Manufacturer Lot Number(s): Lot #114
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 1'-6"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Cascade Steel
Welding Company: RKR Steel Welding
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 1

DIME Test ID: 2023-12-11-1-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 12/28/2023
Date Tested: 12/19/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 3
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111460.4440325.1091648Ok NeckingA Auvinen
211460.4441271.1493798Ok NeckingA Auvinen
311460.4441311.2893889Ok NeckingA Auvinen
UTM 400KIP
Temperature 72 f