Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994615 DEA: 112N1644 EFIS: 1122000151
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8-R3.7/R48.0
Work Description: MICROSURFACING, COLD PLANE, RHMA, PAVEMENT MARKING, & CENSUS SYSTEMS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM 0.7 MILE EAST OF MOUNTAIN SPRINGS ROAD UNDERCROSSING TO 0.2 MILE EAST OF ROUTE 7/8 SEPARATION
Contractor Name: CALMEX ENGINEERING INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-10-13-71
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/20/2023
The quantity of what the sample constitutes: 4 boxes 4 bags
A brief description of the sample: 1/2" RHMA-G
From where was the sample collected: Source
Laboratory sample identification: 9805-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: API Gateway
DIME Test ID: 2023-10-13-71-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/20/2024
Date Tested: 12/11/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies Target - 7.50% -.4 to +.5 / Result 7.98%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
3938.2 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5495.9 g
|
Mass of HMA Sample prior to ignition
|
1557.7 g
|
Corrected Asphalt Binder Content
|
7.98 %
|
Mass Loss
|
125.6 g
|
Mass of aggregate remaining after ignition
|
1432.1 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.08 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
no data0 %
|
Test Temperature
|
538 C
|
DIME Test ID: 2023-10-13-71-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/20/2024
Date Tested: 12/11/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7477.1 grams
|
Mass of oven-dry sample in air for Sample 1
|
1539.1 grams
|
Mass of container filled with the sample and water for Sample 1
|
8378.5 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.414
|
Theoretical maximum density at 25°C (77°F)
|
150.3 lb/ft^3
|