Print Report | Back to Sample Detail

Sample Record for 2023-12-01-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R28.6/37.5
Work Description: REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location Description: SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
Contractor Name: SULLY - MILLER CONTRACTING COMPANY
Contractor Address: 135 S STATE COLLEGE BLVD. 400, BREA, CA 92821
Resident Engineer: Larry J Canuti Structure Rep.: Taghreed Al-khateeb

Sample Information

DIME Sample ID: 2023-12-01-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2023
The quantity of what the sample constitutes: 2 BOXES OF HMA
A brief description of the sample: 1" HMA-A-SP R25 1%LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0596A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BLUE DIAMOND MATERIALS-VICTORVILLE

Material Information

HMA Type: Type A HMA
HMA Grading: 1 inch
Lot number: 3
Sublot number: 39
HMA Mix Number: 300222 CPC R25

Test Results

Test 1 of 1

DIME Test ID: 2023-12-01-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/11/2023
Date Tested: 12/06/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 3156.0 g
Corrected Asphalt Binder Content 4.13 %
Mass Loss 152.5 g
Correction Factor (Percent by mass of HMA Specimen) 0.61 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.09 %
Test Temperature 538 C