Print Report | Back to Sample Detail

Sample Record for 2023-07-13-81

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993339 DEA: 024H9304 EFIS: 0219000027 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-299-44.3/44.9
Work Description: INGOT CURVE IMPROVEMENT - CURVE IMROVEMENT
Location Description: IN SHASTA COUNTY NEAR INGOT FROM 2.7 MILES EAST OF SEAMANS GULCH ROAD TO 1.2 MILES WEST OF DU BOIS ROAD.
Contractor Name: Stimpel Wiebellhaus Inc.
Contractor Address: 1168 Industrial St., REDDING, CA 96002
Resident Engineer: Joel Gasik Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-07-13-81
TL Number from the TL Form: 858124
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 07/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/14/2023
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 2 bags of Combined RAP (1/2-inch)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79298B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis — Northstate Asphalt (Redding, CA)

Material Information

RAP Source: Northstate Asphalt
Aggregate Size: 1/2-inch
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2023-07-13-81-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/28/2023
Date Tested: 07/17/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pbr(uncorrected)=5.95%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3063.0 g
Mass of the specimen and specimen basket assembly prior to ignition 4676.4 g
Mass of HMA Sample prior to ignition 1613.4 g
Corrected Asphalt Binder Content 5.95 %
Mass Loss 99.0 g
Mass of aggregate remaining after ignition 1514.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.00 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C

Test 2 of 3

DIME Test ID: 2023-07-13-81-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 11/28/2023
Date Tested: 07/18/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing) 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) 0.2 %
Aggregate correction factor for the 1/2 in. sieve (% passing) 0.2 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -1.0 %
Aggregate correction factor for the #4 sieve (% passing) -0.4 %
Aggregate correction factor for the #8 sieve (% passing) -0.4 %
Aggregate correction factor for the #16 sieve (% passing) -0.5 %
Aggregate correction factor for the #30 sieve (% passing) -0.8 %
Aggregate correction factor for the #50 sieve (% passing) -0.7 %
Aggregate correction factor for the #100 sieve (% passing) -0.8 %
Aggregate correction factor for the #200 sieve (% passing) -0.6 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 89 %
Cumulative percent passing the 3/8 in. sieve 75 %
Cumulative percent passing the #4 sieve 56 %
Cumulative percent passing the #8 sieve 41 %
Cumulative percent passing the #16 sieve 30 %
Cumulative percent passing the #30 sieve 22 %
Cumulative percent passing the #50 sieve 16 %
Cumulative percent passing the #100 sieve 11 %
Cumulative percent passing the #200 sieve 8.4 %

Test 3 of 3

DIME Test ID: 2023-07-13-81-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/28/2023
Date Tested: 07/17/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmmr=2.547, Gser≈2.775
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7335.7 grams
Mass of oven-dry sample in air for Sample 1 1604.2 grams
Mass of container filled with the sample and water for Sample 1 8310.1 grams
Temperature of Water 76 °F
Specific Gravity for Sample 1 2.547
Theoretical maximum density at 25°C (77°F) 2539.6 kg/m^3