Project Information

Project ID: 215314 DEA: 07333004 EFIS: 0716000298 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5,5-15.1/22.9
Work Description: PROJECT PILOT 1
Location Description: LOS ANGELES COUNTY IN AND NEAR LOS ANGELES ON ROUTE 5 FROM 0.1 MILE SOUTH OF CALZONA STREET TO 0.1 MILE SOUTH OF RIVERSIDE DRIVE AND ROUTE 2 AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER
Contractor Name: Powell Constructors, Inc.
Contractor Address: 8555 Banana Ave, Fontana, CA 92335
Resident Engineer: Jerome Arabe Structure Rep.: Gon Choi

Sample Information

DIME Sample ID: 2023-06-30-80
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/30/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2023
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: Structural Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National RM Vernon

Material Information

The concrete mix design number: S63C653T1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 146812
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW 810 along 5 SB Freeway from sta 804+50 to sta 804+00
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-06-30-80-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/20/2023
Date Tested: 07/28/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4590 psi
Maximum load on cylinder 1 131080 lb
Maximum load on cylinder 2 128320 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours