Print Report | Back to Sample Detail

Sample Record for 2023-10-27-63

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993136 DEA: 120Q3904 EFIS: 1217000003 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-55-4.7
Work Description: RECONSTRUCT REINFORCED STRUCTURAL CONCRETE BRIDGE AND BARRIER.
Location Description: ORANGE COUNTY IN COSTA MESA AT ROUTE 55/73 CONNECTOR
Contractor Name: BEADOR CONSTRUCTION COMPANY
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Adrian Wu Structure Rep.: Noah Bruton

Sample Information

DIME Sample ID: 2023-10-27-63
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2023
The quantity of what the sample constitutes: 3
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 23-0339
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ROBERTSONS - IRVINE

Material Information

The concrete mix design number: RRM18093
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: SB 55 and SB73 Connector
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-10-27-63-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/15/2023
Date Tested: 11/10/2023
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.98 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.09 in^2
Compressive strength (to nearest 10 psi) 3090 psi
Maximum load on cylinder 1 89130 lb
Maximum load on cylinder 2 84480 lb
Compressive strength of cylinder 1 3173.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3007.5 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours 0 hours