Print Report | Back to Sample Detail

Sample Record for 2016-05-31-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210766 DEA: 042G5404 EFIS: 0400021004 QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL-82-14.8/18.1
Work Description: RECONSTRUCT TRAFFIC SIGNALS, DRAINAGE SYSTEMS, SIDEWALKS, AND CURBS.
Location Description: IN SANTA CLARA COUNTY, IN SUNNYVALEAT VARIOUS LOCATIONS.
Contractor Name: OGRADY PAVING INC.
Contractor Address: 2513 Wyandotte St, Mountain View, CA 94043
Resident Engineer: Ali Nikzad Structure Rep.: Reza Shokrpour

Sample Information

DIME Sample ID: 2016-05-31-4
TL Number from the TL Form: C741287
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 05/31/2016
Date that the sample was received by the laboratory/organization performing the testing: 06/01/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mission City Rebar

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): SE15102567
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 5
Diameter of Hoop: 2'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Mission City Rebar
Welding Company: Mission City Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 3

DIME Test ID: 2016-05-31-4-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 06/07/2016
Date Tested: 06/03/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11#5/16mm0.313042098130Bar BrokeBrian
UTM 400KIP
Temperature 72 F

Test 2 of 3

DIME Test ID: 2016-05-31-4-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 06/07/2016
Date Tested: 06/03/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
21#5/16mm0.3131260100840Bar BrokeBrian
UTM 400KIP
Temperature 72 F

Test 3 of 3

DIME Test ID: 2016-05-31-4-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 06/07/2016
Date Tested: 06/03/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
31#5/16mm0.313088099610Bar BrokeBrian
UTM 400KIP
Temperature 72 F