Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G8504 Cty ALA Rte 580 PM R4.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Satinder Grewal |
Date Reported: |
06/16/2016 |
|
Address: |
TL Number: |
180004 |
||
City: |
||||
Project Name: CONSTRUCT A 600 FOOT SOLDIER PILE AND LAGGING WALL WITH GROUND ANCHOR |
||||
Prime Contractor: RGW |
||||
Sample Taken Date: |
05/19/2016 |
Mix Design: |
DDPP8Q2 |
|
Contractor: Unknown |
Location: CONSTRUCT A 600 FOOT SOLDIER PILE AND LAGGING WALL WITH GROUND ANCHOR |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|
1 | 5.97 | 27.99 | 143087 | 3 |
2 | 5.97 | 27.99 | 159619 | 1 |
DIME Test ID: 2016-05-19-13-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5410
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |