Print Report | Back to Sample Detail

Sample Record for 2023-06-06-111

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994093 DEA: 07342804 EFIS: 0717000331 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-14-R27.0/R28.1
Work Description: CONSTRUCT CATCHMENT WALL, ROCK SCALING AND CONCRETE BARRIER.
Location Description: LOS ANGELES COUNTY IN SANTA CLARITA FROM THE NEWHALL AVENUE UNDERCROSSING TO 0.1 MILE SOUTH OF PLACERITA CANYON ROAD UNDERCROSSING
Contractor Name: Powell Constructors, Inc.
Contractor Address: 8555 Banana Avenue, Fontana, CA, 92335
Resident Engineer: Ali MOHSENZADEH Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-06-06-111
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/06/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/06/2023
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: Structural Concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National Ready Mix Concrete Company

Material Information

The concrete mix design number: S73C445T13
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 278970
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RT 14 CW 1470 Barrier Rail sta 1470PLUS00
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-06-06-111-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/09/2023
Date Tested: 07/05/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4650 psi
Maximum load on cylinder 1 130440 lb
Maximum load on cylinder 2 132390 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 29 days
Age of specimen in hours 0 hours