Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040J3004 Cty SON Rte 1 PM 26.7/27.1 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fabio La Serna |
Date Reported: |
12/05/2023 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: CONSTRUCTING RETAINING WALL AND CONFINEMENT SYSTEM TO RESTORE SLIPOUT. |
||||
Prime Contractor: ARGONAUT CONSTRUCTION |
||||
Sample Taken Date: |
11/07/2023 |
Mix Design: |
72105003R |
|
Contractor: Unknown |
Location: SONOMA COUNTY NEAR JENNER FROM 0.3 MILE TO 0.7 MILE NORTH OF MEYERS GRADE ROAD |
|||
Structure unique identifier: 20-E0110 |
||||
Structure name: Slidesville Retaining Wall |
||||
Location of Pour: Walers215to237 |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 51771 | 4120.0 | 1 |
2 | 3.99 | 12.5 | 53133 | 4249.0 | 1 |
3 | 4.00 | 12.57 | 50517 | 4020 | 1 |
DIME Test ID: 2023-11-07-18-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4130
Age of specimen: 7 days
Certified By: Phillip Montes
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 59665 | 4748.0 | 1 |
2 | 4.00 | 12.57 | 62051 | 4938.0 | 1 |
3 | 4.00 | 12.57 | 61021 | 4856 | 3 |
DIME Test ID: 2023-11-07-18-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4850
Age of specimen: 10 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 79471 | 6324.0 | 1 |
2 | 4.00 | 12.57 | 85309 | 6789.0 | 1 |
3 | 4.00 | 12.57 | 74419 | 5922 | 1 |
DIME Test ID: 2023-11-07-18-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6350
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing