Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 031H4804 Cty ED Rte 193 PM 23.4, 23.4, 23.4, 23.4, 23.40 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Nathan Alterton |
Date Reported: |
06/09/2016 |
|
Address: |
TL Number: |
133597 |
||
City: |
||||
Project Name: Emergency Slope Failure -Replace remaining section of gabion wall with soldier pile tieback wall and reconstruct roadway |
||||
Prime Contractor: MCM Construction, Inc |
||||
Sample Taken Date: |
05/19/2016 |
Mix Design: |
AE080AR5WA |
|
Contractor: Unknown |
Location: El Dorado 193 |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 98343 | 3466.4 | 3 |
2 | 6.01 | 28.37 | 93696 | 3302.6 | 1 |
DIME Test ID: 2016-05-19-6-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3380
Age of specimen: 21 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing