Print Report | Back to Sample Detail

Sample Record for 2023-10-27-37

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214336 DEA: 07302404 EFIS: 0713000488 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-101-37/40
Work Description: PADRE JUAN REHAB
Location Description: VEN 101
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 McGrath Street, Suite 101, Ventura, CA 93003
Resident Engineer: Alfred Ira Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-27-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 11/01/2023
The quantity of what the sample constitutes: 20 boxes of hma
A brief description of the sample: 3/4" RHMA-G 0.50% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0560G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite - Santa Paula

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 1556

Test Results

Test 1 of 4

DIME Test ID: 2023-10-27-37-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/29/2023
Date Tested: 11/07/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7353.2 grams
Mass of oven-dry sample in air for Sample 1 2556.1 grams
Mass of container filled with the sample and water for Sample 1 8855.1 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.425
Theoretical maximum density at 25°C (77°F) 2418 kg/m^3

Test 2 of 4

DIME Test ID: 2023-10-27-37-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/29/2023
Date Tested: 11/08/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.2 %
Percent Air Voids 2 3.4 %
Percent Air Voids 3 3.3 %
Percent Air Voids Average 3.3 %

Test 3 of 4

DIME Test ID: 2023-10-27-37-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/29/2023
Date Tested: 11/08/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.347
Bulk Specific Gravity 2 2.343
Bulk Specific Gravity 3 2.345
Average Bulk Specific Gravity 2.345

Test 4 of 4

DIME Test ID: 2023-10-27-37-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/29/2023
Date Tested: 11/07/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2162.0 g
Corrected Asphalt Binder Content 7.47 %
Mass Loss 163.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.04 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.06 %
Test Temperature 538 C