Print Report | Back to Sample Detail

Sample Record for 2023-10-16-34

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993208 DEA: 034F38U4 EFIS: 0321000092 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB-70-16.2/25.8
Work Description: WIDEN SHOULDERS AND IMPROVE CLEAR RECOVERY ZONE.
Location Description: YUBA COUNTY NEAR MARYSVILLE FROM 0.2 MILE NORTH OF LAURELLEN ROAD TO SOUTH HONCUT CREEK BRIDGE
Contractor Name: DeSilva Gates
Contractor Address: 11555 Dublin Boulevard, Dublin, CA 94568
Resident Engineer: Manoharan Selvendran Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-16-34
TL Number from the TL Form: 849509
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/16/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2023
The quantity of what the sample constitutes: 750
A brief description of the sample: 1/2" HMA-O
From where was the sample collected: Source
Laboratory sample identification: 23-239
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DeSilva Gates Aggregates-Marysville

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 18
HMA Mix Number: MD 6730

Test Results

Test 1 of 2

DIME Test ID: 2023-10-16-34-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/30/2023
Date Tested: 10/16/2023
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7343.5 grams
Mass of oven-dry sample in air for Sample 1 2574.1 grams
Mass of container filled with the sample and water for Sample 1 8917.8 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.575
Theoretical maximum density at 25°C (77°F) 2568 kg/m^3

Test 2 of 2

DIME Test ID: 2023-10-16-34-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/30/2023
Date Tested: 10/16/2023
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3942.5 g
Mass of the specimen and specimen basket assembly prior to ignition 6092.3 g
Mass of HMA Sample prior to ignition 2149.8 g
Corrected Asphalt Binder Content 5.29 %
Mass Loss 122.1 g
Mass of aggregate remaining after ignition 2027.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.39 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 0 C