Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994821 DEA: 080J2404 EFIS: 0822000124
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-142-3.5/R3.9
Work Description: HMA (TYPE A), RUBBERIZED HMA (GAP GRADED), CL 2 AB, RDWY EXCAVATION.
Location Description: SAN BERNARDINO COUNTY IN CHINO HILLS FROM 0.5 MILE NORTH OF FELDSPAR DRIVE TO CHINO HILLS PARKWAY
Contractor Name: POWELL CONSTRUCTORS INC
Contractor Address: 644 Pedley Rd., Riverside. CA
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-10-27-20
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/30/2023
The quantity of what the sample constitutes: 16 BOXES OF HMA
A brief description of the sample: 3/4" HMA-A-SP- R15 NO LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0553A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona
DIME Test ID: 2023-10-27-20-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/19/2023
Date Tested: 10/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7353.7 grams
|
Mass of oven-dry sample in air for Sample 1
|
2555.0 grams
|
Mass of container filled with the sample and water for Sample 1
|
8904.5 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.544
|
Theoretical maximum density at 25°C (77°F)
|
2536.6 kg/m^3
|
DIME Test ID: 2023-10-27-20-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/19/2023
Date Tested: 10/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
3.1 %
|
Percent Air Voids 2
|
3.1 %
|
Percent Air Voids 3
|
3.1 %
|
Percent Air Voids Average
|
3.1 %
|
DIME Test ID: 2023-10-27-20-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 12/19/2023
Date Tested: 10/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity
|
2.464
|
Bulk Specific Gravity 2
|
2.465
|
Bulk Specific Gravity 3
|
2.464
|
Average Bulk Specific Gravity
|
2.464
|
DIME Test ID: 2023-10-27-20-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/19/2023
Date Tested: 10/31/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2154.0 g
|
Corrected Asphalt Binder Content
|
4.82 %
|
Mass Loss
|
109.2 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.12 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.13 %
|
Test Temperature
|
538 C
|