Print Report | Back to Sample Detail

Sample Record for 2023-10-20-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215697 DEA: 07318204 EFIS: 0715000286 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-Route 1-4.0/4.2
Work Description: CM/GC Project - Work consists of constructing secant wall and slope restoration
Location Description: near Point Mugu State Park 0.4 mile South of Sycamore Canyon Road.
Contractor Name: Flatiron/Drill Tech, a Joint Venture
Contractor Address: 15335 Fairfield Ranch Rd, Chino Hills, CA 91709
Resident Engineer: Saeid Shakeri Structure Rep.: Azizollah Maghsoudloo

Sample Information

DIME Sample ID: 2023-10-20-31
TL Number from the TL Form: 102023
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 10/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/24/2023
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 23-492
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Associate Ready mixed Concrete

Material Information

The concrete mix design number: 557237SPC
The truck number from where the sample was collected: 4
The batch plant ticket number from where the sample was collected: 7092075
Concrete batch plant: Associated Ready Mix Concrete
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-10-20-31-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/27/2023
Date Tested: 10/27/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.03 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.76 in^2
Compressive strength (to nearest 10 psi) 4020 psi
Maximum load on cylinder 1 50672 lb
Maximum load on cylinder 2 51425 lb
Maximum load on cylinder 3 50975 lb
Compressive strength of cylinder 1 4012.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4052.4 psi
Compressive strength of cylinder 3 3994.9 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours 0 hours