Print Report | Back to Sample Detail

Sample Record for 2023-10-25-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214135 DEA: 09213404 EFIS: 0900000030 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-29.9/41.8
Work Description: ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location Description: INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEPE, AZ. 85284
Resident Engineer: Kris Raber Structure Rep.: Alex Naime-Falcon

Sample Information

DIME Sample ID: 2023-10-25-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/25/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/26/2023
The quantity of what the sample constitutes: 1 Box of HMA
A brief description of the sample: 3/4 HMA WMA R25
From where was the sample collected: Job Site
Laboratory sample identification: HMA-R56
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fisher Sand and Gravel

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2023-10-25-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/27/2023
Date Tested: 10/26/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R56
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4243.8 g
Mass of the specimen and specimen basket assembly prior to ignition 6740.5 g
Mass of HMA Sample prior to ignition 2496.7 g
Corrected Asphalt Binder Content 4.31 %
Mass Loss 111.8 g
Mass of aggregate remaining after ignition 2384.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.17 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2023-10-25-21-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/27/2023
Date Tested: 10/26/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R56
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7310.5 grams
Mass of oven-dry sample in air for Sample 1 2532.7 grams
Mass of container filled with the sample and water for Sample 1 8832.2 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.505
Theoretical maximum density at 25°C (77°F) 155.9 lb/ft^3