Sample Record for 2016-05-09-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209537 DEA: 07295704 EFIS: 0713000025
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R0.0/20.5
Work Description: REPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT.
Location Description: LOS ANGELES COUNTY FROM ORANGE COUNTY LINE TO ROUTE 10/605 SEPARATION
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 1792 KAISER AVENUE, IRVINE CA 92614
Resident Engineer: Mike Wang Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2016-05-09-1
TL Number from the TL Form: L48-PCPI-06-16
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/09/2016
Date that the sample was received by the laboratory/organization performing the testing: 05/11/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 930-16
Structure unique identifier: ROUTE 10 605 SEPARATION
Structure name: CASTING BED
The fabricator/manufacturer/facility name: ROBERTSONS
Material Information
The concrete mix design number: RRM14062
The truck number from where the sample was collected: 19
The batch plant ticket number from where the sample was collected: 1616363
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: B2C INDIVIDUAL PRECAST SALB REPLACEMENT
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2016-05-09-1-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/24/2016
Date Tested: 05/24/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
5.97 in
|
Average diameter of cylinder 2
|
5.97 in
|
Cross sectional area of cylinder 1
|
27.99 in^2
|
Cross sectional area of cylinder 2
|
27.99 in^2
|
Compressive strength (to nearest 10 psi)
|
6460 psi
|
Maximum load on cylinder 1
|
182440 lb
|
Maximum load on cylinder 2
|
179320 lb
|
Compressive strength of cylinder 1
|
6518.0 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
6406.6 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
15 days
|
Age of specimen in hours
|
no data
|