Print Report | Back to Sample Detail

Sample Record for 2023-10-17-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994330 DEA: 09366404 EFIS: 0916000006 QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-58.2/60.4
Work Description: HOT MIX ASPHALT (TYPE A), IMPORTED BORROW, AND ROADWAY EXCAVATION.
Location Description: MONO COUNTY ABOUT 6 MILES NORTH OF LEE VINING FROM ROUTE 167 TO 0.4 MILE NORTH OF CONWAY RANCH ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: David Carruba Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-10-17-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/18/2023
The quantity of what the sample constitutes: 13 Cubic Yards / Mammoth Ready Mix
A brief description of the sample: 5000 Psi Mix / Mammoth
From where was the sample collected: Job Site
Laboratory sample identification: Conc-04
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mammoth Ready Mix

Material Information

The concrete mix design number: 1304.18.25.A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 58900
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: DS-1 Headwall Inlet
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-10-17-26-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/23/2023
Date Tested: 10/23/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: DS-1 Headwall Inlet
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 3.5 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3530 psi
Maximum load on cylinder 1 43390 lb
Maximum load on cylinder 2 44900 lb
Maximum load on cylinder 3 44750 lb
Compressive strength of cylinder 1 3450.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 3570.0 psi
Compressive strength of cylinder 3 3560 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 6 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 2 of 2

DIME Test ID: 2023-10-17-26-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/14/2023
Date Tested: 11/14/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PCC-04
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Apparent mass of submerged cylinder 1 3.5 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5200 psi
Maximum load on cylinder 1 64955 lb
Maximum load on cylinder 2 64740 lb
Maximum load on cylinder 3 66285 lb
Compressive strength of cylinder 1 5170.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 5150.0 psi
Compressive strength of cylinder 3 5270 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 0 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-10-17-26-3ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/19/202311/28/2023Jeffery PuenteCT D09 - Bishop Field LaboratoryDerek Carrington