Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 209037 DEA: 030F6904 EFIS: 0300000100
QA Service Level: 1
DIST-CO-RTE-PM: 03-BUT-70-24.3
Work Description: REPLACE BRIDGE
Location Description: ABOUT 9.5 MILES EAST OF OROVILLE AT FLAG CANYON CREEK BRIDGE 12-140
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: P O BOX 1508, RANCHO CORDOVA, CA 95741
Resident Engineer: Ben Hargrove Structure Rep.: Justin Wood
DIME Sample ID: 2016-04-19-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 04/19/2016
Date that the sample was received by the laboratory/organization performing the testing: 04/21/2016
The quantity of what the sample constitutes: 13
A brief description of the sample: Plain Bearing Pad
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D S Brown
Mfg. Lot Number(s): C1601-5555-10
Material/Compound/Elastomer ID: NA
Samples Representing: 13
Description (size): .25in x 10in x 19in
Comments: Unknown
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): D S Brown
Batch Number: NA
DIME Test ID: 2016-04-19-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/09/2016
Date Tested: 04/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
54
|
Reading #2
|
55
|
Reading #3
|
54
|
Reading #4
|
54
|
Reading #5
|
55
|
Mean
|
54.4
|
DIME Test ID: 2016-04-19-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/09/2016
Date Tested: 04/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
5
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.07 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2685.7 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.07 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2685.7 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.069 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2080.9 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Sample 4 Median Thickness
|
0.068 in
|
Sample 4 Thickness all Within 0.003 inch?
|
Yes
|
Sample 4 Ultimate Tensile
|
2882.4 lbf/in^2
|
Sample 4 Elongation (350% Min)
|
Pass
|
Sample 5 Median Thickness
|
0.071 in
|
Sample 5 Thickness all Within 0.003 inch?
|
Yes
|
Sample 5 Ultimate Tensile
|
2752.8 lbf/in^2
|
Sample 5 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2685.7 lbf/in^2
|
DIME Test ID: 2016-04-19-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/09/2016
Date Tested: 04/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.068 in
|
Sample 1 Tear Strength
|
294.1 lbf / in
|
Sample 2 Median Thickness
|
0.071 in
|
Sample 2 Tear Strength
|
295.8 lbf / in
|
Sample 3 Median Thickness
|
0.065 in
|
Sample 3 Tear Strength
|
292.3 lbf / in
|
Median of the Tear Strength Values
|
294.1 lb/in
|
DIME Test ID: 2016-04-19-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/09/2016
Date Tested: 05/05/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: