STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 040120T4 Cty SF Rte 80 PM 12.6/13.9

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Tom Larwin

Date Reported:

05/06/2016

Address:

TL Number:

Unknown

City:

Project Name: CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES

Prime Contractor: CALIFORNIA ENGINEERING CONTRACTORS, INC.

Sample Taken Date:

03/31/2016

Mix Design:

D101C5E1

Contractor: Unknown

Location: THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL

Structure unique identifier: Unknown

Structure name: Security Booth

Location of Pour: Concrete Slab


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Type of fracture pattern of cylinder
16.0128.351328371
26.0128.351451951

DIME Test ID: 2016-03-31-8-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4290
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 28 days
Certified By: Larry McCrum



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing