Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030H6704 Cty SAC Rte 51 PM 0.0/0.1,10.0/R24.3 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Masoud Saed |
Date Reported: |
10/25/2023 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: INSTALL FIBER OPTIC CABLE SYSTEMS & CONSTRUCT MVPS. |
||||
Prime Contractor: Alfaro Communications Construction, Inc. |
||||
Sample Taken Date: |
09/27/2023 |
Mix Design: |
1615674 |
|
Contractor: Unknown |
Location: SACRAMENTO COUNTY IN AND NEAR ELK GROVE AND SACRAMENTO ON ROUTE 99 FROM GRANT LINE ROAD TO ROUTE 50 AND ON ROUTE 51 FROM ROUTE 50 TO 0.1 MILE SOUTH OF THE FORT SUTTER VIADUCT |
|||
Structure unique identifier: |
||||
Structure name: CIDH CCTV - NB Florin |
||||
Location of Pour: CIDH |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 49027 | 3901.0 | 2 |
2 | 4.03 | 12.76 | 53768 | 4215.0 | 1 |
3 | 4.01 | 12.63 | 48118 | 3810 | 1 |
DIME Test ID: 2023-09-27-3-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3980
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing