Print Report | Back to Sample Detail

Sample Record for 2023-09-20-43

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994431 DEA: 024J1604 EFIS: 0222000145 QA Service Level: 2
DIST-CO-RTE-PM: 02---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-20-43
TL Number from the TL Form: 858050
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Aggregate
Sample Taken Date: 09/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2023
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 2 bags of Lime Treated 3/4-inch Virgin Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: D79353A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Har Creek Construction and Materials - Ward Lake Plant (Litchfield, CA)

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-18-0008::Ward Lake Pit (Litchfield, CA)
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Cold Feed
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2023-09-20-43-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/03/2023
Date Tested: 09/22/2023
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 97 %
Cumulative percent passing the 1/2 in. sieve 80 %
Cumulative percent passing the 3/8 in. sieve 70 %
Cumulative percent passing the #4 sieve 40 %
Cumulative percent passing the #8 sieve 25 %
Cumulative percent passing the #16 sieve 16 %
Cumulative percent passing the #30 sieve 11 %
Cumulative percent passing the #50 sieve 7 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 3.9 %