Print Report | Back to Sample Detail

Sample Record for 2023-09-12-80

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994589 DEA: 081H4914 EFIS: 0819000118 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-18-53.1/69.0
Work Description: REPLACE AC SURF, HMA (TYPE A), AND COLD CENTRAL PLANT RECYCLING.
Location Description: SAN BERNARDINO COUNTY NEAR BIG BEAR LAKE FROM 0.4 MILE EAST OF PINEVIEW DRIVE TO 0.1 MILE NORTH OF RICHARD STREET AND VISALIA AVENUE
Contractor Name: SULLY-MILLER CONTRACTING COMPANY
Contractor Address: Unknown
Resident Engineer: Alfonso Gonzalez Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-12-80
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Sample Organization Contact: (760) 252-9216
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/12/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/13/2023
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 3/4" HMA A
From where was the sample collected: Supplier
Laboratory sample identification: test 2 763 tons out at 0936am
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond Victorville

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 24
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2023-09-12-80-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/25/2023
Date Tested: 09/13/2023
Submitted By Organization: CT D08 - Barstow Field Laboratory 1
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test: SIEVE NO 30 IS OUT OF THE OPERATING RANGE
Test Result Compliance: does not comply
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 0 %
Cumulative percent passing the 1 1/2 in. sieve 0 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 89 %
Cumulative percent passing the 3/8 in. sieve 75 %
Cumulative percent passing the #4 sieve 56 %
Cumulative percent passing the #8 sieve 46 %
Cumulative percent passing the #16 sieve 35 %
Cumulative percent passing the #30 sieve 24 %
Cumulative percent passing the #50 sieve 13 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.2 %