Print Report | Back to Sample Detail

Sample Record for 2023-09-24-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 4844 DEA: 080C8504 MINOR: 08A1357 QA Service Level: 2
DIST-CO-RTE-PM: 08-SBD-10-32.4/R35.2
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-24-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/24/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2023
The quantity of what the sample constitutes: 4 BOXES OF RHMA
A brief description of the sample: 3/4" RHMA-G-SP 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0492G-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: MM-Lake Elsinore

Material Information

HMA Type: RHMA-G
HMA Grading: 3/4 inch
Lot number: 3
Sublot number: 11
HMA Mix Number: 53418180

Test Results

Test 1 of 1

DIME Test ID: 2023-09-24-5-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/04/2023
Date Tested: 09/26/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2132.4 g
Corrected Asphalt Binder Content 7.37 %
Mass Loss 163.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.19 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.12 %
Test Temperature 538 C