Project ID: 994549 DEA: 032G5204 EFIS: 0321000235
QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV,PLA,SIE-20,49,80-VAR
Work Description: PLACE POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS.
Location Description: NEVADA, PLACER AND SIERRA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Court, Suite D, Benicia, CA 94510
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross
DIME Sample ID: 2023-09-19-26
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 09/19/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2023
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / 9800 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000009KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2023-09-19-26-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 11/13/2023
Date Tested: 10/09/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2023-09-19-26-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 11/13/2023
Date Tested: 10/09/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2023-09-19-26-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 11/13/2023
Date Tested: 09/21/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.488 in
|
Sample 1 Ultimate strength
|
8360 psi
|
Sample 1 Thickness
|
0.256 in
|
Sample 1 Area
|
0.1249 in^2
|
Sample 1 Ultimate Strength Actual
|
1044.16 lbs
|
Sample 1 percent elongation
|
19.2 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.488 in
|
Sample 2 Thickness
|
0.256 in
|
Sample 2 Area
|
0.1249 in^2
|
Sample 2 Ultimate strength
|
8385 psi
|
Sample 2 Ultimate Strength Actual
|
1047.29 lbs
|
Sample 2 percent elongation
|
17.8 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.489 in
|
Sample 3 Thickness
|
0.258 in
|
Sample 3 Area
|
0.1262 in^2
|
Sample 3 Ultimate strength
|
8377 psi
|
Sample 3 Ultimate Strength Actual
|
1057.18 lbs
|
Sample 3 percent elongation
|
19.9 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.488 in
|
Sample 4 Thickness
|
0.263 in
|
Sample 4 Area
|
0.1283 in^2
|
Sample 4 Ultimate strength
|
8408 psi
|
Sample 4 Ultimate Strength Actual
|
1078.75 lbs
|
Sample 4 percent elongation
|
18.4 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.489 in
|
Sample 5 Thickness
|
0.258 in
|
Sample 5 Area
|
0.1262 in^2
|
Sample 5 Ultimate strength
|
8439 psi
|
Sample 5 Ultimate Strength Actual
|
1065 lbs
|
Sample 5 percent elongation
|
18.4 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.489 in
|
Sample 6 Thickness
|
0.257 in
|
Sample 6 Area
|
0.1257 in^2
|
Sample 6 Ultimate strength
|
8477 psi
|
Sample 6 Ultimate Strength Actual
|
1065.56 lbs
|
Sample 6 percent elongation
|
17.9 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
8408 psi
|
Percent Elongation Average
|
19 %
|
DIME Test ID: 2023-09-19-26-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 11/13/2023
Date Tested: 10/09/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
44
|
DIME Test ID: 2023-09-19-26-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 11/13/2023
Date Tested: 09/22/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1761.82 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
880.911 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1958.35 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
979.175 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1942.61 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
971.305 psi
|
DIME Test ID: 2023-09-19-26-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 11/13/2023
Date Tested: 09/23/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
77 f
|
Tare weight
|
no data
|
Initial weight
|
100.03 grams
|
Weight at 5 minutes
|
99.955 grams
|
Weight at 10 minutes
|
99.862 grams
|
Weight at 15 minutes
|
99.77 grams
|
Weight at 20 minutes
|
99.679 grams
|
Weight at 25 minutes
|
99.57 grams
|
Weight at 30 minutes
|
99.476 grams
|
Final weight
|
99.48 grams
|
Total weight loss
|
0.55 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
29.566 grams/m^2
|