Print Report | Back to Sample Detail

Sample Record for 2016-04-04-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208967 DEA: 110223U4 EFIS: 1112000102 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5,89-R29.1/R30.5
Work Description: REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT
Contractor Name: Flatiron
Contractor Address: 1770 LA COSTA MEADOWS DRIVE, SAN MARCOS CA 92078
Resident Engineer: Dave Pound Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2016-04-04-5
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 04/04/2016
Date that the sample was received by the laboratory/organization performing the testing: 04/07/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: Coupon Casting
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dotson iron casting

Material Information

Heat Number (s): 0886
Part Number (s): 68 12 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Dotson Iron Castings
Prestressing Manufacturer: DSI

Test Results

Test 1 of 1

DIME Test ID: 2016-04-04-5-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 04/14/2016
Date Tested: 04/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
08860.4980.1948471927895016.7Arnold
UTM 67KIP
Temperature 72 F