Print Report | Back to Sample Detail

Sample Record for 2023-09-20-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-09-20-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 09/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/22/2023
The quantity of what the sample constitutes: 1085 Anchor Heads and 1103 Anchor Head Rings
A brief description of the sample: ASTM A536 Grade 80-55-06 Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Globe Iron Foundry, Inc

Material Information

Heat Number (s): 22723
Part Number (s): SAS GSS Anchor Head and Anchor Head Ring
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Globe Iron Foundry Inc
Prestressing Manufacturer: Stresssteel PT Systems

Test Results

Test 1 of 1

DIME Test ID: 2023-09-20-1-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/28/2023
Date Tested: 09/27/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
227230.5010.197145729710189411.2aauvinen
227230.5020.19792625491112379.2aauvinen
UTM 67kip
Temperature 72 F