Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G5224 Cty ALA Rte 580and680 PM VAR Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
WONDWOSEN ALEMAYEHU |
Date Reported: |
04/27/2016 |
|
Address: |
TL Number: |
155532 |
||
City: |
||||
Project Name: UPGRADE TRANSITION RAILING AND END TREATMENTS. |
||||
Prime Contractor: DIRT AND AGGREGATE INTERCHANGE, INC. |
||||
Sample Taken Date: |
03/30/2016 |
Mix Design: |
xyz123 |
|
Contractor: Unknown |
Location: IN ALAMEDA COUNTY ON RTE 580 FROM GREEVILLE ROAD UC TO CERRITOCREEK AND ON RTE 680 FROM SCOTT RD UC TO SUNOL-KOOPMAN UC |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 154739 | 5528.4 | 1 |
2 | 5.98 | 28.09 | 139713 | 4973.8 | 1 |
DIME Test ID: 2016-03-30-4-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5250
Age of specimen: 28 days
Certified By: Timothy O'Malley
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing