Sample Record for 2023-08-17-75
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994120 DEA: 040J6314 EFIS: 0421000252
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-12-21.2/22.6
Work Description: ROADWAY RESURFACING, INSTALL DRAINAGE SYSTEM, MIDWEST GUARDRAIL SYSTEM
Location Description: SOLANO COUNTY NEAR RIO VISTA FROM MCCLOSKY ROAD TO 0.1 MILE WEST OF AZEVEDO ROAD
Contractor Name: Bay Cities Paving & Grading (David Jimenez)
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Noel Aquino Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2023-08-17-75
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 08/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/17/2023
The quantity of what the sample constitutes: LOT 1 SUBLOT 6
A brief description of the sample: 1/2-INCH-HMA-SP Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Vernalis Dreier Drum 12%RAP
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-39-0041
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Sample Pickup From Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 30240442412V
Test Results
Test 1 of 2
DIME Test ID: 2023-08-17-75-7
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/15/2023
Date Tested: 08/17/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: LOT 1 SUBLOT 6
Teichert Vernalis Drier Drum Plant
12%RAP
Sieve# 4 FAILED
Test Result Compliance: does not comply
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
0 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
0 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
96 %
|
Cumulative percent passing the 3/8 in. sieve
|
79 %
|
Cumulative percent passing the #4 sieve
|
49 %
|
Cumulative percent passing the #8 sieve
|
37 %
|
Cumulative percent passing the #16 sieve
|
23 %
|
Cumulative percent passing the #30 sieve
|
15 %
|
Cumulative percent passing the #50 sieve
|
9 %
|
Cumulative percent passing the #100 sieve
|
6 %
|
Cumulative percent passing the #200 sieve
|
3.4 %
|
Test 2 of 2
DIME Test ID: 2023-08-17-75-8
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/15/2023
Date Tested: 08/17/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: LOT 1 SUBLOT 6
Teichert Vernalis Drier Drum Plant
12%RAP
Test Result Compliance: complies
Additional Comments When Verified:
Tests Assigned to this Sample
DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
2023-08-17-75-1 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 2
Teichert Vernalis Drier Drum Plant
12%RAP
Sieve# 4, 8 FAILED | |
2023-08-17-75-2 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 2
Teichert Vernalis Dreier Drum Plant
12%RAP | |
2023-08-17-75-3 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 4
Teichert Vernalis Drier Drum plant
12%RAP
Sieve# 4 FAILED | |
2023-08-17-75-4 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 4
Teichert Vernalis Drier Drum Plant
12%RAP | |
2023-08-17-75-5 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 5
Teichert Vernalis Drier Drum Plant
Sieve# 4 FAILED
12%RAP | |
2023-08-17-75-6 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | 09/15/2023 | Not scheduled | IGNACIO ARECHIGA | CT D04 - Concord Field Laboratory | LOT 1 SUBLOT 5
Teichert Vernalis Drier Drum Plant
12%RAP | |
844578445884459844608446184462