Sample Record for 2023-07-15-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-50-L0.2/R6.1
Work Description: Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location Description: FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
Contractor Name: FLATIRON WEST INC
Contractor Address: 2100 Goodyear Rd., Benicia, CA 94510
Resident Engineer: Jim Rogers Structure Rep.: Caleb Toy

Sample Information

DIME Sample ID: 2023-07-15-21
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/15/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2023
The quantity of what the sample constitutes: Between 0-100 CY
A brief description of the sample: 6X12 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: C071523-500
Structure unique identifier:
Structure name: Bridge 11, Frame 2, Stem and Soffit
The fabricator/manufacturer/facility name: Elite Ready Mix Bradshaw

Material Information

The concrete mix design number: CT79937S
The truck number from where the sample was collected: 170
The batch plant ticket number from where the sample was collected: 124350
Concrete batch plant: Elite Ready Mix Bradshaw
The fabricator/manufacturer designation for the sample: CT79937S
A detailed description of where the material sample was collected: Jos Site
Where the material sample would have been placed if not sampled: Bridge 11 Frame 2 Stem and Soffit
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-07-15-21-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/11/2023
Date Tested: 09/09/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Cross sectional area of cylinder 1 0 in^2
Cross sectional area of cylinder 2 0 in^2
Compressive strength (to nearest 10 psi) 3700 psi
Maximum load on cylinder 1 103110 lb
Maximum load on cylinder 2 106330 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 56 days
Age of specimen in hours 0 hours