Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-03-15-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/15/2016
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2016
The quantity of what the sample constitutes: 8
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s): S333148-6-1, S333498-5-1, S333516-2-1, S333529-5-1, S333531-2-1, S333532-3-1, S333554-1-1
Number of Coils: Unknown
Group Number: 10843
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 882
Heat Number(s): S0591314-2, S0556815, S0556715, S0592215, S0544815-2, S0544615
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
DIME Test ID: 2016-03-15-7-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 03/24/2016
Date Tested: 03/24/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
7
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .207 | .195 | .195 | .195 | .195 | .195 | .195 | 0.213 | .207 | .195 | .195 | .195 | .195 | .195 | .195 | 0.213 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .208 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 | .207 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 |
| |
DIME Test ID: 2016-03-15-7-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 03/24/2016
Date Tested: 03/24/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
7
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO591314-2 | S333148-6-1 | 0.213 | 59666 | 54615 | 28.4 | 1.61 | Brian | SO556815 | S333498-5-1 | 0.213 | 59069 | | 28.5 | 1.75 | Brian | SO556715 | S333516-2-1 | 0.214 | 59597 | | 27.8 | 1.63 | Brian | SO592215 | S333529-5-1 | 0.217 | 60524 | | 28.1 | 1.79 | Brian | SO544815-2 | S333531-2-1 | 0.215 | 59616 | | 27.8 | 1.67 | Brian | SO544815-2 | S333532-3-1 | 0.215 | 59150 | | 28 | 1.77 | Brian | SO544615 | S333554-1-1 | 0.217 | 60118 | | 28 | 1.84 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|