Print Report | Back to Sample Detail

Sample Record for 2016-03-15-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-03-15-6
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 03/15/2016
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2016
The quantity of what the sample constitutes: 474
A brief description of the sample: .5 Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S128907-5, S128910-2, S128910-4, S128913-2, S128917-7, S128922-3, S128922-6, S128923-3, S128924-3, S128927-2, S128927-5, S128928-5, S128928-6, S128929-6, S128932-1, S128934-2, S128935-2, S128936-2, S128936-6, S128939-2, S128940-2, S128941-1, S128941-4, S128943-1, S128943-3
Number of Coils: 25
Group Number: 10842
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0533615-2, S0533815-2, S0599315-2, S0533715-2, S0534015-3, S0524215, S0524315, S0533215, S0533215-2, S0524915-3, S0524815-3, S0524715-3, S0524615, S0524515-5, S0516916
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Results

Test 1 of 2

DIME Test ID: 2016-03-15-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 03/29/2016
Date Tested: 03/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 25
Dia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.172.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152
.173.165.165.165.165.165.1650.152

Test 2 of 2

DIME Test ID: 2016-03-15-6-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 03/29/2016
Date Tested: 03/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 25
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
SO533615-2S128907-50.152430914025428.61.81Brian
SO533815-2S128910-20.15242863281.68Brian
SO533815-2S128910-40.1524294328.81.65Brian
SO599315-2S128913-20.1524339328.41.61Brian
SO533715-2S128917-70.1524309128.51.78Brian
SO534015-3S128922-30.15242711281.67Brian
SO534015-3S128922-60.1524299728.81.63Brian
SO524215S128923-30.1524291226.51.63Brian
SO524215S128924-30.1524269628.61.76Brian
SO524315S128927-20.1524258828.11.66Brian
SO524315S128927-50.1524287727.11.75Brian
SO533215S128928-50.1524253828.31.72Brian
SO533215S128928-60.1524220628.31.73Brian
SO533215-2S128929-60.1524223828.11.67Brian
SO524915-3S128932-10.1524269828.41.67Brian
SO5244815-3S128934-20.1524278328.41.81Brian
SO5244815-3S128935-20.1524253727.21.59Brian
SO524715-3S128936-20.1524286728.51.84Brian
SO524715-3S128936-60.1524301228.11.78Brian
SO524615S128939-20.1524284128.61.74Brian
S0524615S128940-20.1524262628.11.73Brian
S0524515-3S128941-10.1524294128.31.76Brian
S0524515-3S128941-40.15242979281.69Brian
S0516916S128943-10.1524255828.21.75Brian
S0516916S128943-30.1524277528.31.67Brian
UTM 120KIP
Temperature 70 F
Extensometers E88766