Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994724 DEA: 010M0804 EFIS: 0122000084
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-255-0.5/8.6
Work Description: MICROSURFACING, REPLACE AC SURFACING, AND MODIFY SIGNAL SYSTEMS.
Location Description: HUMBOLDT COUNTY IN EUREKA FROM 0.3 MILE NORTH OF EUREKA CHANNEL BRIDGE TO G STREET IN ARCATA
Contractor Name: DOOLITTLE CONSTRUCTION LLC
Contractor Address: Unknown
Resident Engineer: Ethan Retherford Structure Rep.: Unknown
DIME Sample ID: 2023-08-30-52
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Assurance
Type of Material: Asphaltic Emulsion
Sample Taken Date: 08/30/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/07/2023
The quantity of what the sample constitutes: two emulsion samples
A brief description of the sample: MSE
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: VSS Emultech West Sac
DIME Test ID: 2023-08-30-52-1
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Verified Date: 09/11/2023
Date Tested: 09/07/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
How many beakers will be used to conduct the test?
|
4
|
Beaker 1 Residue
|
64.2 %
|
Beaker 2 Residue
|
64.2 %
|
Beaker 3 Residue
|
64.0 %
|
Beaker 4 Residue
|
64.2 %
|
Percentage of residue
|
64 %
|
DIME Test ID: 2023-08-30-52-2
Test Method: AASHTO T301-22: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Verified Date: 09/11/2023
Date Tested: 09/11/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Final Reading from the testing machine (X)
|
3 cm
|
% Elongation Recovery
|
85 %
|
DIME Test ID: 2023-08-30-52-3
Test Method: AASHTO T49-15: Standard Method of Test for Penetration of Bituminous Materials
Verified Date: 09/11/2023
Date Tested: 09/11/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Was test performed on residue from distillation or evaporation?
|
Evaporation
|
Temperature (C)
|
25 C
|
Load (grams)
|
50 grams
|
Time (sec)
|
5 second
|
Average Penetration
|
42 dmm
|
DIME Test ID: 2023-08-30-52-4
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Particle Charge Cationic Emulsified (Sec. 8))
Verified Date: 09/14/2023
Date Tested: 09/14/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Level of current used
|
8.0 mA
|
Electrode Type
|
Positive
|
DIME Test ID: 2023-08-30-52-5
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Verified Date: 11/02/2023
Date Tested: 11/01/2023
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Efflux time (ET) for test sample
|
23 sec
|
Corrected efflux time as the Saybolt Furol viscosity (Corrected V)
|
23 sec
|
Test efflux temperature
|
25 F
|