Print Report | Back to Sample Detail

Sample Record for 2023-08-29-55

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208973 DEA: 120H1004 EFIS: 1200000180 COOP: 120670 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405,73,405,605-9.3/24.3
Work Description: (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location Description: Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Contractor Name: OC 405 Partners
Contractor Address: 3100 W Lake Center Dr, Santa Ana, CA 92704
Resident Engineer: Hank Alonso (reports) Structure Rep.: Alex Angha (reports)

Sample Information

DIME Sample ID: 2023-08-29-55
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/29/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2023
The quantity of what the sample constitutes: RHMAG, AGG
A brief description of the sample: 1/2 RHMAG
From where was the sample collected: Manufacturer
Laboratory sample identification: 23-0852
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Irvine

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2023-08-29-55-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/07/2023
Date Tested: 09/05/2023
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4018.3 g
Mass of the specimen and specimen basket assembly prior to ignition 5553.5 g
Mass of HMA Sample prior to ignition 1535.2 g
Corrected Asphalt Binder Content 8.03 %
Mass Loss 122.5 g
Mass of aggregate remaining after ignition 1412.7 g
Correction Factor (Percent by mass of HMA Specimen) -0.05 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C

Test 2 of 2

DIME Test ID: 2023-08-29-55-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/07/2023
Date Tested: 09/05/2023
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7309.2 grams
Mass of oven-dry sample in air for Sample 1 1555.6 grams
Mass of container filled with the sample and water for Sample 1 8224.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.429
Theoretical maximum density at 25°C (77°F) 151.2 lb/ft^3