Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212737 DEA: 060S8304 EFIS: 0615000046
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-44.4-45.4
Work Description: TUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location Description: IN FRESNO COUNTY AT TUMEY GULCH.
Contractor Name: Bruce Shumacher
Contractor Address: 2716 S Granite Ct, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Ben Holton
DIME Sample ID: 2023-08-28-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/28/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/28/2023
The quantity of what the sample constitutes: 1132 ton
A brief description of the sample: 1/2 RHMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Coalinga
DIME Test ID: 2023-08-28-15-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/30/2023
Date Tested: 08/29/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
2905.6 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4512.8 g
|
Mass of HMA Sample prior to ignition
|
1607.2 g
|
Corrected Asphalt Binder Content
|
7.73 %
|
Mass Loss
|
137.9 g
|
Mass of aggregate remaining after ignition
|
1469.3 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.66 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.19 %
|
Test Temperature
|
538 C
|