Project ID: 993685 DEA: 09382304 EFIS: 0919000038
QA Service Level: 1
DIST-CO-RTE-PM: 09-KER,MNO-395-Var
Work Description: FURNISH AND INSTALL SIGN STRUCTURE (TRUSS); AND PLACE AND MODIFY CMS.
Location Description: KERN AND MONO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: ALFARO COMMUNICATIONS CONSTRUCTION, INC.
Contractor Address: 15614 S Atlantic Ave, Compton, CA 90221
Resident Engineer: Monty Navarro Structure Rep.: Derek Armon
DIME Sample ID: 2023-08-23-61
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 08/23/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/28/2023
The quantity of what the sample constitutes: 12 PCC 4x8 Cylinders
A brief description of the sample: Structural PCC
From where was the sample collected: Job Site
Laboratory sample identification: PCC-01
Structure unique identifier:
Structure name: CMS LOC 2
The fabricator/manufacturer/facility name: Mammoth ready mix
The concrete mix design number: 1304-18-25A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Truck 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Middle of Truck 1
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-08-23-61-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/30/2023
Date Tested: 08/30/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: 7 Day Break
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
0 in^2
|
Cross sectional area of cylinder 2
|
0 in^2
|
Cross sectional area of cylinder 3
|
0 in^2
|
Compressive strength (to nearest 10 psi)
|
0 psi
|
Maximum load on cylinder 1
|
37590 lb
|
Maximum load on cylinder 2
|
38590 lb
|
Maximum load on cylinder 3
|
40220 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
0 hours
|
DIME Test ID: 2023-08-23-61-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 09/20/2023
Date Tested: 09/20/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: 28 Day Break
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4410 psi
|
Maximum load on cylinder 1
|
55290 lb
|
Maximum load on cylinder 2
|
54625 lb
|
Maximum load on cylinder 3
|
56410 lb
|
Compressive strength of cylinder 1
|
4398.6 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
4345.7 psi
|
Compressive strength of cylinder 3
|
4487.7 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|