Print Report | Back to Sample Detail

Sample Record for 2016-02-25-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209732 DEA: 072881U4 EFIS: 0714000085 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R16.1/R25.8
Work Description: CONSTRUCT CONCRETE PAVEMENT, PRECAST CONCRETE PANELS, AND SLABS.
Location Description: LOS ANGELES COUNTY IN LA CANADA FLINTRIDGE, GLENDALE AND PASADENA FROM DUNSMORE AVENUE UNDERCROSSING TO NORTH LOS ROBLES AVENUE OVERCROSSING
Contractor Name: FLATIRON WEST, INC.
Contractor Address: 1770 LA COSTA MEADOWS DRIVE, SAN MARCOS, CA 92078
Resident Engineer: Sushil Chaudhari Structure Rep.: Mark Amorsolo

Sample Information

DIME Sample ID: 2016-02-25-1
TL Number from the TL Form: 2251
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 02/25/2016
Date that the sample was received by the laboratory/organization performing the testing: 02/29/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 927-51
Structure unique identifier: 210 FWY DUNSMORE TO LOS ROBLES
Structure name: APPROACH SLABS EB WALTONIA WEST CONNECTOR EAST CONNECTOR
The fabricator/manufacturer/facility name: NATIONAL READY

Material Information

The concrete mix design number: S72036
The truck number from where the sample was collected: NP
The batch plant ticket number from where the sample was collected: 192543
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 3
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2016-02-25-1-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/01/2016
Date Tested: 02/29/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.97 in
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 27.99 in^2
Compressive strength (to nearest 10 psi) 3210 psi
Maximum load on cylinder 1 91310 lb
Maximum load on cylinder 2 88490 lb
Compressive strength of cylinder 1 3262.2 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 3161.5 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 4 days
Age of specimen in hours no data