Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.:
DIME Sample ID: 2016-02-19-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 02/19/2016
Date that the sample was received by the laboratory/organization performing the testing: 02/19/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden
Comments: Unknown
Reel/Coil/Pack Number(s): S333630-5, S377424-2
Number of Coils: Unknown
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0584115, S0525515
Mfg. Lot Number(s): Batch No 6
Manufacturer(s): Sumiden
DIME Test ID: 2016-02-19-1-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/24/2016
Date Tested: 02/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
4
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | 0.207 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.215 | 0.207 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.215 | 0.207 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.215 | 0.207 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.196 | 0.215 |
| |
DIME Test ID: 2016-02-19-1-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/24/2016
Date Tested: 02/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
4
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0525515 | S377424-2A | 0.215 | 60100 | 55485 | 28.8 | 1.76 | ARNOLD | S0525515 | S377424-2B | 0.215 | 60343 | | 28.7 | 1.82 | ARNOLD | S0584115 | S333630-5 | 0.215 | 60096 | | 26.8 | 1.72 | ARNOLD | S0584115 | S333630-5 | 0.215 | 60066 | | 28.9 | 1.68 | ARNOLD |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|