Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-02-16-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 02/16/2016
Date that the sample was received by the laboratory/organization performing the testing: 02/18/2016
The quantity of what the sample constitutes: 10
A brief description of the sample: Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s): S800736-3, S800736-5
Number of Coils: 2
Group Number: 10840
Strand Diameter: .375 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0283652
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire
DIME Test ID: 2016-02-16-2-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/22/2016
Date Tested: 02/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .129 | .125 | .125 | .125 | .125 | .125 | .125 | 0.087 | .129 | .125 | .125 | .125 | .125 | .125 | .125 | 0.087 |
| |
DIME Test ID: 2016-02-16-2-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/22/2016
Date Tested: 02/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Coil #S800736-3 is an invalid test due to a grip break, 1 additional strand was tested and passed.
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO283652 | S800736-3 | 0.087 | 24172 | 23307 | 28.7 | 0.69 | Brian | SO283652 | S800736-5 | 0.087 | 24020 | | 28.6 | 1.88 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2016-02-16-2-3
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/22/2016
Date Tested: 02/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO283652 | S800735-3 | 0.087 | 23932 | 22976 | 28.5 | 1.86 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2016-02-16-2-4
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/22/2016
Date Tested: 02/19/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
1
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .129 | .125 | .125 | .125 | .125 | .125 | .125 | 0.087 |
| |