Print Report | Back to Sample Detail

Sample Record for 2023-08-02-74

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993169 DEA: 050A0904 EFIS: 0513000028 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-156-R1.4/R2.0
Work Description: WIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING.
Location Description: MONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD
Contractor Name: Granite Rock (Bryan Jones)
Contractor Address: 5225 Hellyer Ave, Ste 220, San Jose, CA 95138
Resident Engineer: David Hopper Structure Rep.: Dean Russu

Sample Information

DIME Sample ID: 2023-08-02-74
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/02/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2023
The quantity of what the sample constitutes: 43 cubic yards
A brief description of the sample: 3 sets of 4 x 8" cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Graniterock Sand City Batch

Material Information

The concrete mix design number: 57-7-750-E6
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: 18954R
Concrete batch plant: Graniterock Sand City Batch
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute discharge into wheel barrel
Where the material sample would have been placed if not sampled: Bridge Deck
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-08-02-74-3
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 08/09/2023
Date Tested: 08/02/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Slump 4.75 inch

Test 2 of 2

DIME Test ID: 2023-08-02-74-4
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/09/2023
Date Tested: 08/09/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 6.05 in
Average diameter of cylinder 2 6.04 in
Cross sectional area of cylinder 1 28.75 in^2
Cross sectional area of cylinder 2 28.65 in^2
Compressive strength (to nearest 10 psi) 4180 psi
Maximum load on cylinder 1 119920 lb
Maximum load on cylinder 2 119720 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-08-02-74-1ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens08/09/202308/30/2023Wesley RiderCT D05 - Monterey Construction Field LaboratoryFrank Ortega
2023-08-02-74-2ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens08/09/202309/13/2023Wesley RiderCT D05 - Monterey Construction Field LaboratoryFrank Ortega