Sample Record for 2023-08-04-23

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215421 DEA: 042K9504 EFIS: 0417000057 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580-14.4/14.4
Work Description: CONSTRUCT MATERIAL TESTING LABORATORY BUILDING.
Location Description: ALAMEDA COUNTY IN LIVERMORE AT 2201 KITTY HAWK ROAD
Contractor Name: Walsh Construction Company II, LLC (Walsh) - Dominic Fung
Contractor Address: 1390 Willow Pass Road Suite 950, Concord, CA 94520
Resident Engineer: Amir-Fardin Sadeghi-Nedjad Structure Rep.: John Parecadan

Sample Information

DIME Sample ID: 2023-08-04-23
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Department Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/04/2023
Date that the sample was received by the laboratory/organization performing the testing: 08/08/2023
The quantity of what the sample constitutes: 25
A brief description of the sample: 3/4" x 7.5" F3125 Gr 325 Bolts
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LB Construction

Material Information

Rocap Number(s):
Heat Number(s): 10733820
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: F3125 A325
Bolt Length(s): 7.5"
Nut Specification: na
Washer Specification: na
Finish: Plain
Diameter/Size: 3/4
Bolt Mfg. Lot Number: E417F1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 2

DIME Test ID: 2023-08-04-23-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/22/2023
Date Tested: 08/18/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1AE417F10.750048515215.8110.00Wedge Tensileaauvinen
UTM 450kip
Temperature no data

Test 2 of 2

DIME Test ID: 2023-08-04-23-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/22/2023
Date Tested: 08/18/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E417F1
Finish Coating Plain
Product Markings A325 N USA
Size 0.75 in
Bolt Length 7.5 in
Gage Type Pass