Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042K9504 Cty ALA Rte 580 PM 14.4/14.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Amir-Fardin Sadeghi-Nedjad |
Date Reported: |
08/03/2023 |
|
Address: |
TL Number: |
023175 |
||
City: |
||||
Project Name: CONSTRUCT MATERIAL TESTING LABORATORY BUILDING. |
||||
Prime Contractor: Walsh Construction Company II, LLC (Walsh) - Dominic Fung |
||||
Sample Taken Date: |
07/06/2023 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location: ALAMEDA COUNTY IN LIVERMORE AT 2201 KITTY HAWK ROAD |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 62586 | 4907.0 | 1 |
2 | 4.03 | 12.76 | 58103 | 4555.0 | 1 |
3 | 4.02 | 12.69 | 59692 | 4703 | 1 |
DIME Test ID: 2023-07-06-61-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4720
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing