Sample Record for 2023-07-28-25
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215003 DEA: 040J6204 EFIS: 0414000019
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-12.4/21.9
Work Description: REHABILITATE PAVEMENT - RPL APP/DEP SLABS, 14 BRIDGES
Location Description: ALAMEDA COUNTY AT SUNOL AND IN PLEASANTON AND DUBLIN FROM KOOPMANN ROAD UNDERCROSSING TO ALAMEDA COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Eddie Dike Structure Rep.: Betty Geng
Sample Information
DIME Sample ID: 2023-07-28-25
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California Corporation - Lathrop
Sample Organization Contact: (209) 249-4700
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/28/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2023
The quantity of what the sample constitutes: 1 cubic ft. of Concrete for Testing
A brief description of the sample: 1 cubic ft. of Concrete taken from middle of batching
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC
Material Information
The concrete mix design number: 85LV-1K
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 9231 - 9214
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bed 4, 8th Truck - Bed Delta, 5th Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 5
DIME Test ID: 2023-07-28-25-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/31/2023
Date Tested: 07/31/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Bed DELTA
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8.89 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.56 in^2
|
Cross sectional area of cylinder 2
|
12.56 in^2
|
Cross sectional area of cylinder 3
|
12.56 in^2
|
Compressive strength (to nearest 10 psi)
|
6540 psi
|
Maximum load on cylinder 1
|
81015 lb
|
Maximum load on cylinder 2
|
81315 lb
|
Maximum load on cylinder 3
|
84255 lb
|
Type of fracture pattern of cylinder 1
|
4
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
3 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|
Test 2 of 5
DIME Test ID: 2023-07-28-25-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/31/2023
Date Tested: 07/31/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Bed 4
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8.88 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.56 in^2
|
Cross sectional area of cylinder 2
|
12.56 in^2
|
Cross sectional area of cylinder 3
|
12.56 in^2
|
Compressive strength (to nearest 10 psi)
|
6390 psi
|
Maximum load on cylinder 1
|
82715 lb
|
Maximum load on cylinder 2
|
79240 lb
|
Maximum load on cylinder 3
|
78695 lb
|
Type of fracture pattern of cylinder 1
|
4
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
3 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|
Test 3 of 5
DIME Test ID: 2023-07-28-25-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 07/31/2023
Date Tested: 07/28/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Flow: 22"
VSI: 0
Bed 4 & Delta
Test Result Compliance:
Additional Comments When Verified:
Test 4 of 5
DIME Test ID: 2023-07-28-25-4
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 07/31/2023
Date Tested: 07/28/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Bed 4
Test Result Compliance:
Additional Comments When Verified:
Test 5 of 5
DIME Test ID: 2023-07-28-25-5
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 07/31/2023
Date Tested: 07/28/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Bed Delta
Test Result Compliance:
Additional Comments When Verified: