Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-01-22-5
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 01/22/2016
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2016
The quantity of what the sample constitutes: 43
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s): S333623-2 S333627-2 S333627-5 S333631-5 S333635-5 S333641-3 S333642-1 S333645-3 S333645-4 S333646- 2 S333646-7 S333649- 2 S333652-1 S333653-1 S333653- 2 S333654-2 S333654-3 S377400-3 S377400-5 S377414-4
Number of Coils: 20
Group Number: 10838
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0585015 S0585215 S0584115 S0584515 S0584715 S0584215 S0584615 S0585315 S0595115 S0585115 S0584415 S0584315
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden
DIME Test ID: 2016-01-22-5-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/03/2016
Date Tested: 02/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
20
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .207 | .196 | .196 | .196 | .196 | .196 | .196 | 0.215 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .196 | .196 | .196 | .196 | .196 | .196 | 0.214 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 | .206 | .197 | .197 | .197 | .197 | .197 | .197 | 0.216 |
| |
DIME Test ID: 2016-01-22-5-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/03/2016
Date Tested: 02/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
20
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO585015 | S333623-2 | 0.215 | 59930 | 54959 | 28.4 | 1.76 | Brian | SO585215 | S333627-2 | 0.214 | 60435 | | 28.5 | 1.77 | Brian | SO585215 | S333627-5 | 0.214 | 60797 | | 28.4 | 1.76 | Brian | SO584115 | S333631-5 | 0.214 | 60731 | | 28.3 | 1.84 | Brian | SO584515 | S333635-5 | 0.214 | 60919 | | 28.7 | 1.98 | Brian | SO584715 | S333641-3 | 0.214 | 60098 | | 28.8 | 1.8 | Brian | SO584715 | S333642-1 | 0.214 | 60313 | | 29 | 1.96 | Brian | SO584215 | S333645-3 | 0.214 | 60010 | | 29 | 1.82 | Brian | SO584215 | S333645-4 | 0.214 | 59980 | | 28.7 | 1.82 | Brian | SO584615 | S333646-2 | 0.214 | 60116 | | 28.5 | 1.79 | Brian | SO584615 | S333646-7 | 0.214 | 60162 | | 29.2 | 1.8 | Brian | SO585315 | S333649-2 | 0.214 | 60149 | | 28.5 | 1.78 | Brian | SO585315 | S333652-1 | 0.214 | 60520 | | 28.6 | 1.87 | Brian | SO595115 | S333653-1 | 0.216 | 59960 | | 28.2 | 1.8 | Brian | SO595115 | S333653-2 | 0.216 | 59987 | | 28.1 | 1.73 | Brian | SO585115 | S333654-2 | 0.214 | 60453 | | 28.3 | 1.75 | Brian | SO585115 | S333654-3 | 0.214 | 60685 | | 28.4 | 1.83 | Brian | SO584415 | S377400-3 | 0.216 | 60616 | | 28.3 | 1.71 | Brian | SO584415 | S377400-5 | 0.216 | 60206 | | 27.4 | 1.68 | Brian | SO584315 | S377414-4 | 0.216 | 60716 | | 27.9 | 1.71 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|