Print Report | Back to Sample Detail

Sample Record for 2016-01-22-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-01-22-5
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 01/22/2016
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2016
The quantity of what the sample constitutes: 43
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S333623-2 S333627-2 S333627-5 S333631-5 S333635-5 S333641-3 S333642-1 S333645-3 S333645-4 S333646- 2 S333646-7 S333649- 2 S333652-1 S333653-1 S333653- 2 S333654-2 S333654-3 S377400-3 S377400-5 S377414-4
Number of Coils: 20
Group Number: 10838
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0585015 S0585215 S0584115 S0584515 S0584715 S0584215 S0584615 S0585315 S0595115 S0585115 S0584415 S0584315
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden

Test Results

Test 1 of 2

DIME Test ID: 2016-01-22-5-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 02/03/2016
Date Tested: 02/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 20
Dia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
.207.196.196.196.196.196.1960.215
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.197.197.197.197.197.1970.216
.206.197.197.197.197.197.1970.216
.206.196.196.196.196.196.1960.214
.206.196.196.196.196.196.1960.214
.206.197.197.197.197.197.1970.216
.206.197.197.197.197.197.1970.216
.206.197.197.197.197.197.1970.216

Test 2 of 2

DIME Test ID: 2016-01-22-5-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 02/03/2016
Date Tested: 02/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 20
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
SO585015S333623-20.215599305495928.41.76Brian
SO585215S333627-20.2146043528.51.77Brian
SO585215S333627-50.2146079728.41.76Brian
SO584115S333631-50.2146073128.31.84Brian
SO584515S333635-50.2146091928.71.98Brian
SO584715S333641-30.2146009828.81.8Brian
SO584715S333642-10.21460313291.96Brian
SO584215S333645-30.21460010291.82Brian
SO584215S333645-40.2145998028.71.82Brian
SO584615S333646-20.2146011628.51.79Brian
SO584615S333646-70.2146016229.21.8Brian
SO585315S333649-20.2146014928.51.78Brian
SO585315S333652-10.2146052028.61.87Brian
SO595115S333653-10.2165996028.21.8Brian
SO595115S333653-20.2165998728.11.73Brian
SO585115S333654-20.2146045328.31.75Brian
SO585115S333654-30.2146068528.41.83Brian
SO584415S377400-30.2166061628.31.71Brian
SO584415S377400-50.2166020627.41.68Brian
SO584315S377414-40.2166071627.91.71Brian
UTM 120KIP
Temperature 70 F
Extensometers E88766