Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214336 DEA: 07302404 EFIS: 0713000488
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-101-37/40
Work Description: PADRE JUAN REHAB
Location Description: VEN 101
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 4820 McGrath Street, Suite 101, Ventura, CA 93003
Resident Engineer: Alfred Ira Structure Rep.: Unknown
DIME Sample ID: 2023-07-21-39
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Soil
Sample Taken Date: 07/21/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2023
The quantity of what the sample constitutes: 5460 sqft
A brief description of the sample: Native - Subgrade
From where was the sample collected: Job Site
Laboratory sample identification: 23-1116
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: n/a
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CTM 231 Test Holes
Where the material sample would have been placed if not sampled:
DIME Test ID: 2023-07-21-39-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 07/26/2023
Date Tested: 07/21/2023
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Standard Count Density
|
3027 g/cc
|
Count or Density 1
|
6576 g/cc
|
Count or Density 2
|
5367 g/cc
|
Count or Density 3
|
5691 g/cc
|
Standard Count Moisture
|
1072 g/cc
|
Moisture Count 1
|
413 g/cc
|
Moisture Count 2
|
303 g/cc
|
Moisture Count 3
|
337 g/cc
|
Sum of Count or Density
|
17634.00 g/cc
|
Average of Count or Density
|
5878.00 g/cc
|
Sum of Moisture Count
|
1053.00 g/cc
|
Average of Moisture Count
|
351.00 g/cc
|
Count Ratio Density
|
1.94
|
Count Ratio Moisture
|
0.33
|
Calculated Percent Relative Compaction
|
92.1 %
|
Reported Percent Relative Compaction
|
92 %
|
DIME Test ID: 2023-07-21-39-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 07/26/2023
Date Tested: 07/21/2023
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
1.99
|
Highest adjust wet density
|
2.16
|
Relative compaction
|
92
|
% Moisture
|
14.4 %
|
Optimum Moisture
|
15.9 %
|