Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042J7404 Cty SM Rte 101 PM 0.9/23.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Peter Lam |
Date Reported: |
09/29/2023 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: REMOVE BRIDGES (PORTIONS), BRIDGE BARRIERS, CONCRETE BARRIERS, & HMA. |
||||
Prime Contractor: Graniterock (Matt Christie) |
||||
Sample Taken Date: |
07/21/2023 |
Mix Design: |
57S590 |
|
Contractor: Unknown |
Location: SAN MATEO COUNTY AT VARIOUS LOCATIONS FROM UNIVERSITY AVENUE OVERCROSSING TO SIERRA POINT OFF RAMP OVERCROSSING |
|||
Structure unique identifier: 35-0081G |
||||
Structure name: N101-S84 Connector |
||||
Location of Pour: Wingwall |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.03 | 12.76 | 73808 | 5786.0 | 1 |
2 | 4.03 | 12.76 | 76381 | 5988.0 | 1 |
3 | 4.02 | 12.69 | 65958 | 5197 | 1 |
DIME Test ID: 2023-07-21-30-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5660
Age of specimen: 70 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing